Interpreting the Test Run indicator

The description below is presented twice since the fault counter behaves differently depending on what type of DTC that is being monitored. See the article Interpreting information in the Graph view for further information.

Unconfirmed DTC limit is +127

The description below is applicable when the Unconfirmed limit and the Failed limit are the same i.e. +127. Please refer to the article Interpreting the Fault counter for further details about the Fault counter.

Note

Note

The set and reset criteria are applicable for the row This Cycle in the Test Run indicator.

 

Figure description (number 1-2)

Fig. No.

Description

1

Failed limit

2

Passed limit

 

Figure description (number 3-4)

Name

Description

Fault

Symptom

Fault tracing

Set criteria

Reset criteria

Test completed this control module operation cycle.

The fault counter reaches the Failed limit or the Passed limit. See fig. no. 3.

A new control module operation cycle started. See fig. no. 4.

N/A

N/A

N/A

Test started this control module operation cycle.

Test run criteria fulfilled. See fig. no. 3.

A new control module operation cycle started. See fig. no. 4.

N/A

N/A

N/A

 
Fig. 408: Illustrative example of the Test Run indicator
 

Color legend

Color

Description

Pending

Failed

Passed

#1 - #2 in the figure represent control module operation cycles.

Unconfirmed DTC limit is less than +127

The description below is applicable when the Unconfirmed limit is less than the Failed limit i.e. less than +127. Please refer to the article Interpreting the Fault counter for further details about the Fault counter.

Note

Note

The set and reset criteria are applicable for the row This Cycle in the Test Run indicator.

 

Figure description (number 1-3)

Fig. No.

Description

1

Failed limit

2

Unconfirmed limit

3

Passed limit

 

Figure description (number 4-6)

Name

Description

Fault

Symptom

Fault tracing

Set criteria

Reset criteria

Test completed this control module operation cycle.

The fault counter reaches the Failed limit or the Passed limit. See fig. no. 5.

A new control module operation cycle started. See fig. no. 6.

N/A

N/A

N/A

Test started this control module operation cycle.

Test run criteria fulfilled. See fig. no. 4.

A new control module operation cycle started. See fig. no. 6.

N/A

N/A

N/A

 
Fig. 409: Illustrative example of the Test Run indicator
 

Color legend

Color

Description

Pending

Failed

Unconfirmed

Passed

#1 - #2 in the figure represent control module operation cycles.